Check the width detection is correct

WHAT YOU NEED 

Standard Personal Protective Equipment

CAUTIONWhen using the manual mode, make sure that everything and everyone is clear of moving parts to prevent damage or injuries.

  1. Open the PEWIN32PRO program.
  2. Select Watch Window from the View drop-down menu at the top of the PEWIN32PRO window.
  3. Press the Insert key and add the MeasuredTimberWidth (P759) variable to the Watch Window.
  4. Using the Manual Mode window, clamp a 90‑mm-wide board into the saw.
  5. Make sure the MeasuredTimberWidth variable in the Watch Window is within 2 mm of the actual width of the board.
  6. Hold down the red STOP button on the operator console for 3 seconds and remove the timber from the saw.
  7. Repeat steps 4 to 6 with at least a 120‑mm-wide board into the saw.
  8. If the width detection is not correct for either board, contact Vekta Automation for help in recalibrating.